CÓDIGO DE ALARMA |
Descripción |
1 |
Error de escritura de la memoria |
2 |
Sonda Entrada agua rota o desconectada |
3 |
Sonda Salida agua rota o desconectada |
4 |
Sonda Aire exterior rota o desconectada |
5 |
Sonda Batería rota o desconectada |
6 |
Sonda Descarga rota o desconectada |
7 |
Sonda Aspiración rota o desconectada |
8 |
Transductor AP roto o desconectado |
9 |
Transductor BP roto o desconectado |
10 |
Alarma bajo calentamiento (EVD) |
11 |
Alarma LOP (EVD) |
12 |
Alarma MOP (EVD) |
13 |
Alarma alta temperatura Condensación (EVD) |
14 |
Alarma baja temperatura de aspiración (EVD) |
15 |
Alarma válvula (EVD) |
16 |
Autotuning válvula (EVD) |
17 |
Cierre de emergencia válvula (EVD) |
18 |
Alarma Rango error (EVD) |
19 |
Alarma Válvula valor pin fuera de límite |
20 |
Alarma flujostato |
21 |
Alarma antihielo |
22 |
Alarma Magnetotérmico bomba |
23 |
Alarma baja presión |
24 |
Alarma alta presión |
25 |
Alarma baja presión grave |
26 |
Alarma magnetotérmico ventilador |
27 |
Temperatura elevada de gas impelente: |
28 |
Válvula de inversión de ciclo averiada: Bajo delta P. La válvula de inversión del ciclo podría estar averiada o bloqueada |
29 |
Delta P mayor que el permitido en el start up (por defecto = 20 bar). No causa bloqueo de la máquina |
30 |
Compresor Force Off |
31 |
Alarma Superación de tiempo de límites operativos |
32 |
Arranque fallido compresor. No causa bloqueo de la máquina |
33 |
Diferencial de presión inferior al especificado (0,3 bar en 60 seg) |
34 |
Sobrecorriente |
35 |
Sobrecarga motor compresor |
36 |
Exceso de tensión CC BUS |
37 |
Insuficiente tensión CC BUS |
38 |
Exceso de temperatura drive |
39 |
Insuficiente temperatura drive |
40 |
Exceso de corriente Hardware |
41 |
Exceso de temperatura compresor |
42 |
Error módulo IGBT – Fallo interno. Sustituir Inverter |
43 |
Error CPU. |
44 |
Parámetros por defecto |
45 |
CC bus ripple. Controlar las tensiones de las fases que alimentan el inverter |
46 |
Comunicación entre inverter y uPC3 ausente |
47 |
Fallo en sensor de temperatura drive |
48 |
Autoconfiguración fallida |
49 |
Drive inverter inhabilitado. Controlar puentes en caja de conexiones de inverter Power Plus |
50 |
Error de fases motor |
51 |
Ventilador de refrigeración inverter averiado |
52 |
Speed fault. Pérdida de potencia del compresor. Controlar tipo de compresor configurado |
53 |
PFC fault (alarma que se verifica con PFC habilitado mientras el bus CC está muy bajo) |
54 |
PFC overload trip (esta alarma no estará presente en las nuevas versiones del firmware) |
55 |
Input voltage error (cuando la alimentación baja de los 170 V con el motor en movimiento) |
56 |
Error STO 1 |
57 |
Error STO 2 |
58 |
Fallo de la conexión a tierra (solo para monofásica) |
59 |
Internal error 1 (ADC conversion sync fault) |
60 |
Internal error 2 (Hw sync fault) |
CÓDIGO DE ALARMA |
Descripción |
61 |
Inverter drive overload |
62 |
uC safety Drive Stopped |
63 |
99:Inverter unexpected stop |
64 |
Inverter offline |
65 |
01:Inverter uSafety current measurement fault |
66 |
02:Inverter uSafety current unbalanced fault |
67 |
03:Inverter uSafety over current |
68 |
04:Inverter uSafety STO alarm |
69 |
05:Inverter uSafety STO hardware alarm |
70 |
06:Inverter uSafety main power supply missing |
71 |
07:Inverter uSafety HW fault on inverter command buffer |
72 |
08:Inverter uSafety HW fault on heater circuitry |
73 |
09:Inverter uSafety data communication fault |
74 |
10:Inverter uSafety compressor stall detect |
75 |
11:Inverter uSafety DC bus over current |
76 |
12:Inverter uSafety HWF DC bus current alarm |
77 |
13:Inverter uSafety DC bus voltage alarm |
78 |
14:Inverter uSafety HWF DC bus voltage alarm |
79 |
15:Inverter uSafety input voltage alarm |
80 |
16:Inverter uSafety HWF input voltage alarm |
81 |
Alta presión de presostato |
82 |
Alarma resumen Térmicas |
83 |
Desescarche forzado por alta temperatura de gas impelente |
84 |
Alarma alta temperatura entrada de agua |
85 |
Alarma force off bajo contenido de agua |
86 |
Error carga parámetros inverter |
87 |
Inverter no compatible con el seleccionado |
88 |
Arranque fallido espera de siguiente intento |
89 |
Número máximo de arranques fallidos |
90 |
Alta temperatura gas impelente de envolvente |
91 |
Alarma envolvente zona 2: elevada relación de compresión |
92 |
Alarma envolvente zona 3: alta temperatura gas impelente |
93 |
Alarma envolvente zona 4: elevada corriente compresor |
94 |
Alarma envolvente zona 5: baja presión de aspiración |
95 |
Alarma envolvente zona 6: baja relación de compresión |
96 |
Alarma envolvente zona 7: bajo diferencial de presión |
97 |
Alarma envolvente zona 8: baja presión de descarga |
98 |
Alarma envolvente zona 9: baja presión de aspiración |
99 |
Alarma envolvente zona 10: alta temperatura gas impelente |
100 |
17:Inverter uSafety DC bus power alarm |
101 |
18:Inverter uSafety HWF power mismatch |
102 |
19:Inverter uSafety NTC over temperature |
103 |
20:Inverter uSafety NTC under temperature |
104 |
21:Inverter uSafety NTC fault |
105 |
22:Inverter uSafety HWF sync fault |
106 |
23:Inverter uSafety invalid parameter |
107 |
24:Inverter uSafety FW fault |
108 |
25:Inverter uSafety HW fault |
109 |
26:Inverter uSafety – reseved |
110 |
27:Inverter uSafety – reseved |
111 |
28:Inverter uSafety – reseved |
112 |
29:Inverter uSafety – reseved |
113 |
30:Inverter uSafety – reseved |
114 |
31:Inverter uSafety – reseved |
115 |
32:Inverter uSafety – reseved |
116 |
Sonda Remota DHW averiada |
117 |
Fallo Sonda entrada multifunción (acumulación instalación) |